Swimming Pool Heating Cost Calculator

Enter a heating task or measured energy to get a heating-cost range.

Tariffs, heat loss and measured-energy mode

Your result will appear here

Enter your measurements, then choose Calculate.

Save inputs and show input record

Inputs and units used
How we estimate
Formula, sources and blank printable worksheet

    Initial electricity references: EIA July 2026 and BLS September 2026. These observations define an editable scenario range, not local price bounds. Set both rates to your tariff for a single-rate result.

    HEAT-COST-1: useful total Btu = events × (water heat + heat-up loss × hours) + maintenance loss × maintenance hours. Electricity kWh = Btu/(3412.14 × COP/efficiency); therms = Btu/(100000 × efficiency).

    Calculation version 1.0 uses historical engineering references for arithmetic, not current residential law.

    Blank measurement record
    Quantity / unitReadingSource and date
    Energy mode________________________________
    Water volume________________________________
    Volume unit________________________________
    Temperature unit________________________________
    Starting water temperature________________________________
    Target water temperature________________________________
    Heat-up hours________________________________
    Energy conversion________________________________
    COP (heat pump) or efficiency fraction (gas/resistance)________________________________
    Source model and air/water/humidity rating conditions________________________________
    Heat-up event count________________________________
    Electricity reference low, USD/kWh________________________________
    Electricity reference high, USD/kWh________________________________
    Currency label________________________________
    Gas reference low, USD/therm________________________________
    Gas reference high, USD/therm________________________________

    Mark missing measurements Unknown. Keep exact model, source revision and assumptions with this worksheet. Report a calculation or source correction with reproducible inputs.

    Quiet pool water and surrounding deck in natural light

    The swimming pool heating cost calculator prices a heat task. You can use a water warm-up or measured energy. It keeps useful heat apart from energy bought. You can edit the dated rates.

    For a warm-up, enter water quantity and temperature rise. Add known heat loss for the entered hours. Divide useful Btu by 3,412.14 and efficiency or COP to get electricity kWh. Gas uses 100,000 Btu per therm, then an efficiency adjustment.

    Multiply energy by its rate. If loss is unknown, the answer is a lower bound. Measured energy can replace these heat assumptions, but it needs a matching period and rate.

    On this page7

    Swimming pool heating cost calculator task

    Use the capacity calculator to establish useful heat and required output. This tool uses the same water-heat equation: US gallons × 8.33 × positive °F rise. Add constant heat-up loss × heat-up hours for each event. Add maintenance loss × maintenance hours separately.

    Do not include the same hours in both loads. A target below the starting temperature gives no water-only warming demand. Maintenance can still need heat, but it is a separate entered task. Unknown weather is not inferred from a postal code.

    Heating cost calculator reference rates

    The editable electricity rates represent the source periods named here. One is 0.1831 USD/kWh from EIA July home-use data. The other is 0.196 USD/kWh from BLS September US city data. Their methods and periods differ. Neither is a local price limit.

    The gas rates use 1.700 USD/therm from BLS September data and about 2.55 USD/therm from EIA July home-use data. To get the latter, divide 26.45 USD/Mcf by 10.37 therms/Mcf. Replace both rates with what you pay for the next unit of fuel. Keep fixed fees and any extra taxes separate. They stay unknown unless entered.

    Worked water-only event

    For 15,000 US gallons and a 10°F rise, useful heat is 1,249,500 Btu, about 366.19 kWh. At a supplied COP of 5, electrical input is about 73.24 kWh. At an artificial 0.20 currency/kWh, the event costs about 14.65 currency units before losses.

    For gas efficiency 0.80, the same useful load needs 15.61875 therms. Use a therm rate for that result. A price per cubic foot cannot be substituted without heat-content conversion. The heating-type comparison explains the different conversion factors.

    Measured-use mode

    Enter measured electricity kWh or gas therms for the relevant period. The expense is that energy multiplied by the stated rate. Do not add a calculated heat-up load again when it is already included in the measured use.

    Keep other loads outside the measurement boundary when comparing heaters. If a meter includes circulation-pump electricity, identify it. This mode does not infer useful heat from a bill total or claim that weather was identical between two measurement periods.

    Save the heating scenario

    The heat equation is checked against Pentair's engineering reference, printed page 27. The NIST SI guide supplies the IT Btu conversion. Print or download volume, temperatures, losses, rates, efficiency conditions and calculation version 1.0 together.

    FAQ

    Does the estimate include buying a heater?

    No. This tool estimates energy cost for the task. Buying and fitting a heater are separate costs. So are permits and service. Fixed utility fees are separate too. Unknown items stay unknown. A heat result also cannot prove that a model fits your circuit.

    Can I use one COP for a whole season?

    Only as a stated scenario. A heat pump's COP and output vary with the conditions. One warm-air figure cannot predict a whole season. Use source data that matches each period, or measured input for that period. Note the limits when you hold COP constant in an estimate.

    Verdict on heating cost

    Use the swimming pool heating cost calculator to compare the same heat load under clear rates and conditions. Read the cost guide when separating maintenance from warm-up. A source-labelled lower bound remains a lower bound after a price is applied.